Apr 122014
 

Recently I decided it was time to beef up my storage link between my demonstration vSphere environment and my storage system. My existing setup included a single HP DL360p Gen8, connected to a Synology DS1813+ via NFS.

I went out and purchased the appropriate (and compatible) HP 4 x 1Gb Server NIC (Broadcom based, 4 ports), and connected the Synology device directly to the new server NIC (all 4 ports). I went ahead and configured an iSCSI Target using a File LUN with ALUA (Advanced LUN features). Configured the NICs on both the vSphere side, and on the Synology side, and enabled Jumbo frames of 9000 bytes.

I connected to the iSCSI LUN, and created a VMFS volume. I then configured Round Robin MPIO on the vSphere side of things (as always I made sure to enable “Multiple iSCSI initators” on the Synology side).

I started to migrate some VMs over to the iSCSI LUN. At first I noticed it was going extremely slow. I confirmed that traffic was being passed across all NICs (also verified that all paths were active). After the migration completed I decided to shut down the VMs and restart to compare boot times. Booting from the iSCSI LUN was absolutely horrible, the VMs took forever to boot up. Keep in mind I’m very familiar with vSphere (my company is a VMWare partner), so I know how to properly configure Round Robin, iSCSI, and MPIO.

I then decided to tweak some settings on the ESXi side of things. I configured the Round Robin policy to IOPS=1, which helped a bit. Then changed the RR policy to bytes=8800 which after numerous other tweaks, I determined achieved the highest performance to the storage system using iSCSI.

This config was used for a couple weeks, but ultimately I was very unsatisfied with the performance. I know it’s not very accurate, but looking at the Synology resource monitor, each gigabit link over iSCSI was only achieving 10-15MB/sec under high load (single contiguous copies) that should have resulted in 100MB/sec and higher per link. The combined LAN throughput as reported by the Synology device across all 4 gigabit links never exceeded 80MB/sec. File transfers inside of the virtual machines couldn’t get higher then 20MB/sec.

I have a VMWare vDP (VMWare Data Protection) test VM configured, which includes a performance analyzer inside of the configuration interface. I decided to use this to test some specs (I’m too lazy to actually configure a real IO/throughput test since I know I won’t be continuing to use iSCSI on the Synology with the horrible performance I’m getting). The performance analyzer tests run for 30-60 minutes, and measure writes and reads in MB/sec, and Seeks in seconds. I tested 3 different datastores.

Synology  DS1813+ NFS over 1 X Gigabit link (1500MTU):

  • Read 81.2MB/sec, Write 79.8MB/sec, 961.6 Seeks/sec

Synology DS1813+ iSCSI over 4 x Gigabit links configured in MPIO Round Robin BYTES=8800 (9000MTU):

  • Read 36.9MB/sec, Write 41.1MB/sec, 399.0 Seeks/sec

Custom built 8 year old computer running Linux MD Raid 5 running NFS with 1 X Gigabit NIC (1500MTU):

  • Read 94.2MB/sec, Write 97.9MB/sec, 1431.7 Seeks/sec

Can someone say WTF?!?!?!?! As you can see, it appears there is a major performance hit with the DS1813+ using 4 Gigabit MPIO iSCSI with Round Robin. It’s half the speed of a single link 1 X Gigabit NFS connection. Keep in mind I purchased the extra memory module for my DS1813+ so it has 4GB of memory.

I’m kind of choked I spent the money on the extra server NIC (as it was over $500.00), I’m also surprised that my custom built NFS server from 8 years ago (drives are 4 years old) with 5 drives is performing better then my 8 drive DS1813+. All drives used in both the Synology and Custom built NFS box are Seagate Barracuda 7200RPM drives (Custom box has 5 X 1TB drives configured RAID5, the Synology has 8 x 3TB drives configured in RAID 5).

I won’t be using iSCSI  or iSCSI MPIO again with the DS1813+ and actually plan on retiring it as my main datastore for vSphere. I’ve finally decided to bite the bullet and purchase an HP MSA2024 (Dual Controller with 4 X 10Gb SFP+ ports) to provide storage for my vSphere test/demo environment. I’ll keep the Synology DS1813+ online as an NFS vDP backup datastore.

Feel free to comment and let me know how your experience with the Synology devices using iSCSI MPIO is/was. I’m curious to see if others are experiencing the same results.

UPDATE – June 6th, 2014

The other day, I finally had time to play around and do some testing. I created a new FileIO iSCSI Target, I connected it to my vSphere test environment and configured round robin. Doing some tests on the newly created datastore, the iSCSI connections kept disconnecting. It got to the point where it wasn’t usable.

I scratched that, and tried something else.

I deleted the existing RAID volume and I created a new RAID 5 volume and dedicated it to Block I/O iSCSI target. I connected it to my vSphere test environment and configured round robin MPIO.

At first all was going smoothly, until again, connection drops were occurring. Logging in to the DSM, absolutely no errors were being reported and everything was fine. Yet, I was at a point where all connections were down to the ESXi host.

I shut down the ESXi host, and then shut down and restarted the DS1813+. I waited for it to come back up however it wouldn’t. I let it sit there and waited for 2 hours for the IP to finally be pingable. I tried to connect to the Web interface, however it would only load portions of the page over extended amounts of time (it took 4 hour to load the interface). Once inside, it was EXTREMELY slow. However it was reporting that all was fine, and everything was up, and the disks were fine as well.

I booted the ESXi host and tried to connect to it, however it couldn’t make the connection to the iSCSI targets. Finally the Synology unit became un-responsive.

Since I only had a few test VMs loaded on the Synology device, I decided to just go ahead and do a factory reset on the unit (I noticed new firmware was available as of that day). I downloaded the firmware, and started the factory reset (which again, took forever since the web interface was crawling along).

After restarting the unit, it was not responsive. I waited a couple hours and again, the web interface finally responded but was extremely slow. It took a couple hours to get through the setup page, and a couple more hours for the unit to boot.

Something was wrong, so I restarted the unit yet again, and again, and again.

This time, the alarm light was illuminated on the unit, also one of the drive lights wouldn’t come on. Again, extreme unresponsiveness. I finally got access to the web interface and it was reporting the temperature of one of the drives as critical, but it said it was still functioning and all drives were OK. I shut off the unit, removed the drive, and restarted it again, all of a sudden it was extremely responsive.

I removed the drive, hooked it up to another computer and confirmed that it was failed (which it was).

I replaced the drive with a new one (same model), and did three tests. One with NFS, one with FileIO iSCSI, and one with BlockIO iSCSI. All of a sudden the unit was working fine, and there was absolutely NO iSCSI connections dropping. I tested the iSCSI targets under load for some time, and noticed considerable performance increases with iSCSI, and no connection drops.

Here are some thoughts:

  • Two possible things fixed the connection drops, either the drive was acting up all along, or the new version of DSM fixed the iSCSI connection drops.
  • While performance has increased with FileIO to around ~120-160MB/sec from ~50MB/sec, I’m still not even close to maxing out the 4 X 1Gb interfaces.
  • I also noticed a significant performance increase with NFS, so I’m leaning towards the fact that the drive had been acting up since day one (seeks per second increased by 3 fold after replacing the drive and testing NFS). I/O wait has been significantly reduced
  • Why did the Synology unit just freeze up once this drive really started dying? It should have been marked as failed instead of causing the entire Synology unit not to function.
  • Why didn’t the drive get marked as failed at all? I regularly performed SMART tests, and checked drive health, there was absolutely no errors. Even when the unit was at a standstill, it still reported the drive as working fine.

Either way, the iSCSI connection drops aren’t occurring anymore, and performance with iSCSI is significantly better. However, I wish I could hit 200MB+/sec.

At this point it is usable for iSCSI using FileIO, however I was disappointed with BlockIO performance (BlockIO should be faster, no idea why it isn’t).

For now, I have an NFS datastore configured (using this for vDP backup), although I will be creating another FileIO iSCSI target and will do some more testing.

Update – August 16, 2019: Please see these additional posts regarding performance and optimization:

Apr 112014
 

Earlier today I was doing some work in my demonstration vSphere environment, when I had to modify some settings of one of my VMs that are setup as the latest version (which means you can only edit the settings inside of the vSphere Web Client).

To my surprise, when logging in, immediately I received an error: “ManagedObjectReference: type = Datastore, value = datastore-XXXX, serverGuid = XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXX refers to a managed object that no longer exists or has never existed“. Also, after clicking OK, I noticed that lots of information being presented inside of the vSphere web client was inaccurate. Some Virtual Machines were being reported as sitting on different datastores (they were at one point weeks ago, however since were moved). Also, it was reporting that some Virtual Machines were off, when in fact they were on and running.

Symptoms:

-Errors about missing datastores on log on to the vSphere Web Client.

-Virtual Machines were being reported as off (turned off) even though they were running.

-Viewing VMs in vSphere client, reporting they are being stored on a different datastore then they actually are.

-Disconnecting and (re) connecting hosts have no effect on issue.

 

This freaked me out, it was a true “Uhh Ohh” moment. Something was corrupt. Keep in mind that ALL information in the vSphere client was correct and accurate, it was only the vSphere Web client that was having issues.

 

Anyways, I tried a bunch of things to fix it, and spent hours working on the problem. FINALLY I came up with a fix. If you are running in to this issue, PLEASE take a snapshot of your vCenter Server before attempting to fix it, so that you can roll back if you screw anything up (which I had to do multiple times, lol).

The Fix:

1) Stop the “VMWare vCenter Inventory Service”.

2) Delete the “data” folder inside of “Program Files\VMware\Infrastructure\Inventory Service”.

3) Open a Command Prompt with elevated privileges. Change your working directory to “Program Files\VMware\Infrastructure\Inventory Service\scripts”.

4) Run “createDB.bat”, this will reset and create a Inventory Service database.

5) Run “is-change-sso.bat https://computername.domain.com:7444/lookupservice/sdk “[email protected]” “SSO_PASSWORD”. Change the computername.domain.com to your FQDN for your vCenter server, and change the SSO_PASSWORD to your Single Signon Admin password.

6) Start the “VMWare vCenter Inventory Service”. At this point, if you try to log on to the vSphere Web Client, it will error with: “Client is not authenticated to VMware Inventory Service”. We’ve already won half the battle.

7) We now need to register the vCenter Server with the newly reset Inventory Service. In an elevated Command Prompt (that we opened above), changed the working path to: “Program Files\VMware\Infrastructure\VirtualCenter Server\isregtool”.

8) Run “register-is.bat https://computername.domain.com:443/sdk https://computername.domain.com:10443 https://computername.domain.com:7444/lookupservice/sdk”. Change computername.domain.com to your FQDN for your vCenter server.

9) Restart the “VMware VirtualCenter Server” service. This will also restart the Management Web services.

 

BAM, it’s fixed! I went ahead and restarted the entire server that the vCenter server was running on. After this, all was good, and everything looked great inside of the vSphere Web Client. I’m actually noticing it’s running WAY faster, and isn’t as glitchy as it was before.

Happy Virtualizing! 🙂

Jul 082013
 

Recently I needed to upgrade and replace my storage system which provides basic SMB dump file services, iSCSI, and NFS to my internal network and vSphere cluster. As most of you know, in the past I have traditionally created and configured my own storage systems. For the most part this has worked fantastic, especially with the NFS and iSCSI target services being provided and built in to the Linux OS (iSCSI thanks to Lio-Target).

A few reasons for the upgrade…

  1. I need more storage
  2. I need a pre-packaged product that comes with warranty.

Taking care of the storage size was easy (buy more drives), however I needed to find a pre-packaged product that fits my requirements for performance, capabilities, stability, support, and of course warranty. iSCSI and NFS support was an absolute must!

Some time ago, when I first started working with Lio-Target before it was incorporated and merged in to the linux kernel, I noticed that the parent company Rising Tide Systems mentioned they also provided the target for numerous NAS and SAN devices available on the market, Synology being one of them. I never thought anything of this as back then I wasn’t interesting in purchasing a pre-packaged product, until my search for a new storage system.

Upon researching, I found that Synology released their 2013 line of products. These products had a focus on vSphere compatibility, performance, and redundant network connections (either through Trunking/Link aggregation, or MPIO iSCSI connections).

The device that caught my attention for my purpose was the DS1813+.

DS1813+
Synology DS1813+

Synology DS1813+ Specifications:

  • CPU Frequency : Dual Core 2.13GHz
  • Floating Point
  • Memory : DDR3 2GB (Expandable, up to 4GB)
  • Internal HDD/SSD : 3.5″ or 2.5″ SATA(II) X 8 (Hard drive not included)
  • Max Internal Capacity : 32TB (8 X 4TB HDD) (Capacity may vary by RAID types) (See All Supported HDD)
  • Hot Swappable HDD
  • External HDD Interface : USB 3.0 Port X 2, USB 2.0 Port X 4, eSATA Port X 2
  • Size (HxWxD) : 157 X 340 X 233 mm
  • Weight : 5.21kg
  • LAN : Gigabit X 4
  • Link Aggregation
  • Wake on LAN/WAN
  • System Fan : 120x120mm X2
  • Easy Replacement System Fan
  • Wireless Support (dongle)
  • Noise Level : 24.1 dB(A)
  • Power Recovery
  • Power Supply : 250W
  • AC Input Power Voltage : 100V to 240V AC
  • Power Frequency : 50/60 Hz, Single Phase
  • Power Consumption : 75.19W (Access); 34.12W (HDD Hibernation);
  • Operating Temperature : 5°C to 35°C (40°F to 95°F)
  • Storage Temperature : -10°C to 70°C (15°F to 155°F)
  • Relative Humidity : 5% to 95% RH
  • Maximum Operating Altitude : 6,500 feet
  • Certification : FCC Class B, CE Class B, BSMI Class B
  • Warranty : 3 Years

This puppy has 4 gigabit LAN ports, and 8 SATA bays. There’s tons of reviews on the internet praising Synology, and their DSM operating system (based on embedded linux) on the internet, so I decided to live dangerously and went ahead and placed an order for this device, along with 8 X Seagate 3TB Barracuda drives.

Unfortunately, it’s extremely difficult to get your hands on a DS1813+ in Canada (I’m not sure why). After numerous orders placed and cancelled with numerous companies, I finally found a distributor who was able to get me one. I’ll just say the wait was totally worth it. Initially I also purchased the 2GB RAM add-on as well, so I had this available when the DS1813+ arrived.

I was hoping to take a bunch of pictures, and do thorough testing with the unit before throwing it in to production, however right from the get go, it was extremely easy to configure and use, so right away I had it running in production. Sorry for the lack of pics! 🙂

I did however get a chance to setup the 8 drives in RAID 5, and configured an iSCSI block based target. The performance was fantastic, no problems whatsoever. Even maxing out one gigabit connection, the resources of the unit were barely touched.

I’m VERY impressed with the DSM operating system. Everything is clearly spelled out, and you have very detailed control of the device and all services. Configuration of SMB shares, iSCSI targets, and NFS exports is extremely simple, yet allows you to configure advanced features.

After testing out the iSCSI performance, I decided to get the unit ready for production. I created 2 shared folders, and exported these via NFS to my ESXi hosts. It was very simple, quick, and the ESXi hosts had absolutely no problems connecting to the exports.

One thing that really blew me away about this unit, is the performance. Immediately after configuring the NFS exports, mounting them and using Storage vMotion to migrate 14 live virtual machines to the DS1813+ I noticed MASSIVE performance gains. The performance gains were so large, it put my old custom storage system to shame. And this is really interesting, considering my old storage system, while custom, is actually spec’d way higher then the storage unit (CPU, RAM, and the SATA controller). I’m assuming the DS1813+ has numerous kernel optimizations for storage, and at the same time does not have the overhead of a fully Linux distribution. This also means it’s more stable since you don’t have tons of applications running in the background that you don’t need.

After migrating the VMs I noticed that the virtual machines were running way faster, and were may more responsive. I’m assuming this is due to increased IOPS.

Either way I’m extremely happy with the device and fully recommend it. I’ll be posting more blog articles later detailing configuration of services in detail such as iSCSI, NFS, and some other things. I’m already planning on picking up an additional DS1513+ (5 bay unit) to act as a storage server for VM backups which I perform using GhettoVCB.

Update – August 16, 2019: Please see these additional posts regarding performance and optimization:

Jun 092012
 

So there I was… Had a custom built vSphere cluster, 3 hosts, iSCSI target (setup with Lio-Target), everything running fine, smoothly, perfect… I’m done right? NOPE!

Most of us who care, are concerned about our Disaster Recovery or Backup solution. With virtualization things get a little bit interesting in the fact that either you have a CRAZY large setup, and can use the VMware backup stuff, or you have a smaller environment and want something simple, easy to use, and with a low footprint. Configuring a backup and/or disaster recovery solution for a virtualized environment may be difficult and complicated, however after it’s fully implemented; management, use, and administration is easy, and don’t forget about the abilities and features you get with virtualization.

Reasons why virtualization rocks when it comes to backup and disaster recovery:

-Unlike traditional backups you do not have to install a bare OS to run the backup software to restore over

-You can restore to hardware that is not like nor similar to the original hardware

-Backups are now simple files that can be easily moved, transported, copied, and saved on to normal or non-normal media (you could save an entire system on to a USB key if it was big enough). On a 2TB external USB drive, you could have a backup of over 16+ virtual machines!

-Ease of recovery: Copy the backed up VM files to host/datastore, and simply hit play. Restore complete and you’re up and running!

 

So with all that in mind, here we go! (Scroll to bottom of post for a quick conclusion).

For my solution, here are some of the requirements I had:

1) Utilize snapshots to take restorable backups while the VMs are running (no downtime).

2) Move the backups to a different location while running (this could be a drive, NFS export, SMB share, etc…).

3) Have the backups stored somewhere easy to access where I can move them to a removable external USB drive to take off-site. This way, I have fast disk-to-disk access to restore backups in the event my storage system goes down or RAID array is lost (downtime would be minimal), or in the event of something more serious like a fire, I would have the USB drive off-site to restore from. Disk-to-disk backups could happen on a daily basis, and disk-to-USB could be done weekly and taken off-site.

4) In the event of a failure, be able to bring USB drive onsite, transfer VMs back and be up and running in no time.

 

So with this all in mind, I started designing a solution. My existing environment (without backup) composed of:

2 X HP DL360 G5 Servers (running ESXi)

1 X HP ML350 G5 Server (running ESXi)

1 X Super Micro Intel Xeon Server (Running CentOS 6 & Lio-Target backports: providing iSCSI VMFS)

2 X HP MSA20 Storage Units

 

First, I need a way to create snapshots of my 16+ virtual machines. After, I would need to have the snapshots moved to another location (such as a backup server). There is a free script available called ghettoVCB. ghettoVCB is a “Free alternative for backup up VM’s for ESX(i) 3.5, 4.x+ & 5.x” and is available (along with tons of documentation) at: http://communities.vmware.com/docs/DOC-8760. This script is generally ran on the ESXi host, generates a snapshot and clones it to a seperate datastore configured on that host. It does this for all virtual machines named in the VM list you specify, or for all VMs on the host if a specific switch is passed to ghettovcb.sh.

So now that we have the software, we need to have a location setup to back up to. We could either create a new iSCSI target, or we could setup a new Linux server and have a RAID array configured and formatted with ext4 and exported via NFS. This would allow us to have the NFS setup as a datastore on ESXi (so we can backup to the NFS export), and afterwards be able to access the backups natively in Linux to copy/move to a external drive formatted with EXT4.

We configure a new server, running CentOS 6 with enough storage to backup all VMs. We create NFS exports and mount these to all the ESXi hosts. We copy the ghettovcb script to a location on the NFS export so it’s accessible to all hosts easily (without having to update the script on each host individually), and we create lists for each physical host containing the names of the virtual machine it virtualizes. We then edit the ghettovcb.sh file to specify the new destination datastore (the backup datastore) and how we want it to back up.

When executing:

./ghettovcb.sh -f esxserverlist01

It creates the snapshot for each VM in the list for that host, clones it to the destination datastore (which in my setup is the NFS export on the new backup server), then deletes the snapshot when the backup is complete, finally moving on to the next VM and repeating the process until done. The script needs to be ran on all hosts, and list files for VMs have to be created for each host.

We now have a backup server and have done a disk-to-disk backup of our virtual machines. We can now plug in a large external USB drive to the backup server, and simply copy over the backups to it.

 

I do everything manually because I like to confirm everything is done and backed up properly, however you can totally create scripts to automate the whole process. After this we have our new backup solution!

 

Quick recap:

1) Setup a new backup server with enough disk space to back up all VMs. Setup an NFS export and mount it to ESXi hosts.

2) Download and configure the ghettoVCB script. Run the script on each ESXi host to disk-to-disk backup your VMs to your new backup server.

3) Copy the backup files from the backup server to a external USB drive that has enough space. Take off-site.

 

I have had to restore a couple VMs in the past due to a damaged RAID array, and I did so using a backup from above. It worked great! I will create a post on the restore process sometime in the future (for now feel free to look at the ghettoVCB documentation)!

Jun 092012
 

Recently, I’ve started to have some issues with the HP MSA20 units attached to my SAN server at my office. These MSA20 units stored all my Virtual Machines inside of a VMFS filesystem which was presented to my vSphere cluster hosts over iSCSI using Lio-Target. In the last while, these logical drive has just been randomly disappearing, causing my 16+ virtual machines to just halt. This always requires me to shut off the physical hosts, shut off the SAN server, shut off the MSA20s, and bring everything all the way back up. This causes huge amounts of downtime, and it just a pain in the butt…

I decided it was time for me to re-do my storage system. Preferably, I would have purchased a couple HP MSA60s and P800 controllers to hook it up to my SAN server, but unfortunately right now it’s not in the budget.

A few years ago, I started using software RAID. In the past I was absolutely scared of it, thought it was complete crap, and would never have touched it, but my opinion drastically changed after playing with it, and regularly using it. While I still recommend businesses to use Hardware based RAID systems, especially for mission critical applications, I felt I could try out software RAID for the above situation since it’s more of a “hobby” setup.

I read that most storage enthusiasts use either the Super Micro AOC-SASLP-MV8, or the LSI SAS 9211-8i. Both are based off different chipsets (both of which are widely used in other well known cards), and both have their own pro’s and con’s.

During my research, I noticed a lot of people who run Windows Home Server were utilizing the AOC Super Micro Card. And while using WHS, most reported no issues whatsoever, however it was a different story when reading posts/blog articles from people using Linux. I don’t know how accurate this was, but apperently a lot of people had issues with this card under heavy load, and some just couldn’t get it running inside of linux.

Then there is the LSA 9211-8i (which is the same as the extremely popular IBM M1015). This bad boy supports basic RAID operations (1, 0, 10), but most people use it with JBOD and simply use Linux MD Software RAID. While there was numerous complaints about users having issues with their systems even detecting their card, other users also reported issues caused by the BIOS of this card (too much memory for the system to boot). When people did get this card working though, I read of mostly NO issues under Linux. Spent a few days confirming what I already had read and finally decided to make the purchase.

Both cards support SAS/SATA, however the LSI card supports 6Gb/sec SAS/SATA. Both also have 2 internal SFF8087 Mini-SAS connectors to hook up a total of 8 drives directly, or more using an SAS expander. The LSI card uses a PCIe (V.2) 8x slot, vs the AOC-SASLP which uses PCIe (V.1) 4x slot.

I went to NCIX.com and ordered the LSI 9211-8i along with 2 breakout cables (Card Part#: LSI00194, Cable Part#: CBL-SFF8087OCF-06M). This would allow me to hook up a total of 8 drives (even though I only plan to use 5). I already have an old computer I already use with an eSATA connector to a Sans Digital SATA Expander for NFS, etc… that I plan on installing the card in to. I also have an old Startech SATABAY5BK enclosure which will hold the drives and connect to the controller. Finished case:

Server with disk enclosures (StarTech SATABAY5BK)

(At this point I have the enclosure installed along with 5 X 1TB Seagate 7200.12 Barracuda drives)

Finally the controller showed up from NCIX:

LSI SAS 9211-8i

I popped this card in the computer (which unfortunately only had PCIe V1), and connected the cables! This is when I ran in to a few issues…

-If no drives were connected, the system would boot and I could succesfully boot to CentOS 6.

-If at all I pressed CTRL+C to get in to the cards interface, the system would freeze during BIOS POST.

-If any drives were connected and detected by the cards BIOS, the system would freeze during BIOS POST.

I went ahead and booted in to CentOS 6. Downloaded the updated firmware and BIOS and flashed the card. The flashing manual was insane, but had to read it all to make sure I didn’t break anything. First I updated both the firmware and BIOS (which went ok), however I couldn’t convert the card from IR firmware to IT firmware due to errors. I google’d this and came up with a bunch of articles, but this one: http://brycv.com/blog/2012/flashing-it-firmware-to-lsi-sas9211-8i/ was the only one that helped and pointed me in the right direction. Essentially just stating you have to use the DOS flasher, erase the card (MAKING SURE NOT TO REBOOT OR YOU’D BRICK IT), and then flashing the IT Firmware. This worked for me, check out his post! Thanks Bryan!

Anyways, after updating the card and converting it to the IT firmware. I still had the BIOS issue. I tried the card in another system, and still had a bunch of issues. I finally removed 1 of 2 video cards and populated the card in a Video Card slot, and I finally could get in to the BIOS. First I enabled staggered spin-up (to make sure I don’t blow the PSU on the computer with a bunch of drives starting up at once), changed some other settings to optimize, and finally disabled the boot BIOS, and changed the option for the adapter to be disabled for boot, and only available to the OS. When removing the card, and putting it in the target computer, this worked. Also noticed that the staggered spin-up started during the Linux kernel startup when initializing the card. Here’s a copy of the kernel log:

mpt2sas version 08.101.00.00 loaded
mpt2sas 0000:06:00.0: PCI INT A -> Link[LNKB] -> GSI 18 (level, low) -> IRQ 18
mpt2sas 0000:06:00.0: setting latency timer to 64
mpt2sas0: 64 BIT PCI BUS DMA ADDRESSING SUPPORTED, total mem (3925416 kB)
mpt2sas 0000:06:00.0: irq 24 for MSI/MSI-X
mpt2sas0: PCI-MSI-X enabled: IRQ 24
mpt2sas0: iomem(0x00000000dfffc000), mapped(0xffffc900110f0000), size(16384)
mpt2sas0: ioport(0x000000000000e000), size(256)
mpt2sas0: sending message unit reset !!
mpt2sas0: message unit reset: SUCCESS
mpt2sas0: Allocated physical memory: size(7441 kB)
mpt2sas0: Current Controller Queue Depth(3305), Max Controller Queue Depth(3432)
mpt2sas0: Scatter Gather Elements per IO(128)
mpt2sas0: LSISAS2008: FWVersion(13.00.57.00), ChipRevision(0x03), BiosVersion(07.25.00.00)
mpt2sas0: Protocol=(Initiator,Target), Capabilities=(TLR,EEDP,Snapshot Buffer,Diag Trace Buffer,Task Set Full,NCQ)
mpt2sas0: sending port enable !!
mpt2sas0: host_add: handle(0x0001), sas_addr(0x5000000080000000), phys(8)
mpt2sas0: port enable: SUCCESS

SUCCESS! Lot’s of SUCCESS! Just the way I like it! Haha, card intialized, had access to drives, etc…

Configured the RAID 5 Array using a 256kb chunk size. I also changed the “stripe_cache_size” to 2048 (the system has 4GB of RAM) to increase the RAID 5 performance.

cd /sys/block/md0/md/

echo 2048 > stripe_cache_size

At this point I simply formatted the drive using EXT4. Configured some folders, NFS exports, and then used Storage vMotion to migrate the Virtual Machines from the iSCSI target, to the new RAID5 array (currently using NFS). The main priority right now was to get the VMs off the MSA20 so I could at least create a backup after they have been moved. Next step, I’ll be re-doing the RAID5 array, configuring the md0 device as a iSCSI target using Lio-Target, and formatting it with VMFS. The performance of this Software RAID5 array is already blowing the MSA20 out of the water!

So there you have it! Feel free to post a comment if you have any questions or need any specifics. This setup is rocking away now under high I/O with absolutely no problems whatsoever. I think I may go purchase another 1-2 of these cards!